MMO or Platinised coating is an excellent Electrical conductor and giving well chemical stability, when it will be coated on Titanium or Niobium base, even in very low pH environments.
Major Failure of Cathodic Protection systems are due to the break down of the electrical connection between the cable joints and anodes. These failures will take place, when the anodes connections are jointed by resin based seals.
To prevent such a failures, we developed the hybrid method of "CPCC" cable joints by hot fusion crimping of anode with the copper conductor, covered by polymer cable sheath. After the crimping, the joints are 100% Quality Assured on...

  • Conductivity test on Electrical Connection.
  • Helium (vacuum) leak test on joints.
  • In-house test for dimension, adhesion & coating thick of Anode.
  • Mechanical and chemical analysis of Electrical cable.
  • Mechanical & Chemical analysis of Titanium substrate.


MMO Coating & its Current output

MMO coating greatly prolong the life of the anode (low wear rate) and provide excellent chemical corrosion resistance such as acid condition. The standard outputs are as below. However, coating loading may be adjusted to suit a particular current density or design life.

Electrolyte Maximum Current Density Maximum Current Density Anode Life
Carbonaceous Backfill 50 A/m2 20 years
Calcined Petroleum Coke 100 A/m2 20 years
Fresh Water 100 A/m2 20 years
Brackish Water 300 A/m2 20 years
Sea Water 600 A/m2 20 years

SPECIFICATIONS FOR CPCC MMO TUBULAR ANODES

Anode Type Anode Length Anode Dia  Amps Range Design Life 
mm in mm in 5-70oC 0-5oC
Sea water
CPCCSWT20 500 20 19 0.75 20.0 3.0 15 Years
CPCCSWT40 1000 40 19 0.75 40.0 6.0
CPCCSWT25 500 20 25 1.00 25.0 5.0
CPCCSWT50 1000 40 25 1.00 50.0 10.0
CPCCSWT75 1220 48 32 1.25 75.0 15.0
Mud (Sea Water)
CPCCSWT3 500 20 19 0.75 3.0 1.5 15 Years
CPCCSWT6 1000 40 19 0.75 6.0 3.0
CPCCSWT4 500 20 25 1.00 4.0 1.5
CPCCSWT8 1000 40 25 1.00 8.0 3.0
CPCCSWT12 1220 48 32 1.25 12.0 4.5
Mud (Fresh & Brackish Water)
CPCCSWT3 500 20 25 1.00 3.0 1.5 20 Years
CPCCSWT6 1000 40 25 1.00 6.0 3.0
Fresh water, Brackish water, Coke in soil
CPCCSWT2.5 500 20 19 0.75 2.5 1.25 20 Years
CPCCSWT3.6 610 24 19 0.75 3.6 1.80
CPCCSWT5 1000 40 19 0.75 5.0 2.50
CPCCSWT6 1220 48 19 0.75 6.0 3.00
CPCCSWT4 500 20 2.5 1.00 4.0 2.00
CPCCSWT8 1000 40 2.5 1.00 8.0 4.00
CPCCSWT5 1500 60 2.5 1.00 5.0 2.50
CPCCSWT7.5 2250 90 2.5 1.00 7.5 3.80
CPCCSWT10 3000 120 2.5 1.00 10.0 5.00
 
#-48, Noothanchary, Madambakkam, Chennai - 600073, India. Web: http://www.cpanode.com