Impressed Current Cathodic Protection (ICCP) Anodes

MMO Coated / Platinized Titanium & Niobium Anodes

Platinised Titanium Rod supply to Korea (South) for Cathodic Protection Application

clock November 13, 2023 15:07 by author admin

Platinised Titanium Rod supply to Korea (South) for Cathodic Protection Application

Platinized Titanium anodes are widely used for various applications including Impressed Current Cathodic Protection (ICCP) such as hard chrome plating, metal electroplating, electronics, semiconductor industry, chemical process engineering, electroplating, electro dialysis, electroforming (Conforming anodes), electrochemical sensing, electro winning and metal refining, electrolytic regeneration of chromic acid, sodium hypochlorite production, Electro synthesis of organic and inorganic chemicals Etc.,

This platinized titanium anode are highly competent to survive the atmosphere whereas high chemical and environmental corrosion risk exist such as.

v  Deep & conventional ground beds.

v  Jetties in fresh, brackish and salt-water electrolytes.

v  Water tanks.

v  Lock Gates.

v  Intake Screens.

v  Marine application.

Surface resistance of Platinized titanium anodes are very less by nature while compare conventional electrodes, so power efficiency of an entire process become superior.

Platinum layer on titanium substrate become stable during an entire design life, so this anodes are also known Dimensionally Stable Anode.

Platinized titanium anodes are manufactured with a titanium base structure, in the form of either plate, rod, wire, mesh or tube (or any shape as per request). Catalyst thick on surface: Platinum (in micron thick) 2.5 to 7.5; MMO (in micron thick) 8.0 to 10.0.

Advantages

v  Excellent corrosion resistance and catalytic activity

v  Low hydrogen evolution potential, can be utilized as both an anode and cathode

v  Great current efficiency

v  Reversible polarity

v  Excellent coating adhesion

Current Output: Current output is dependent on…

A] Coating catalyst

B] Wire size

C] Coating thickness

D] Substrate

E] Application

F] Design life

G] Temperature.

 

Anodes are available with the current output of 1.7 A to 13 A/each. Or the operational CD is over 50A / ft2. Anode Size: Available in six standard sizes of rod anodes as follows, 3.0 mm dia; 6.0 mm dia; 10.0 mm dia; 12.0 mm dia; 20.0 mm dia; 25.0 mm dia. Other sizes are available on request.

 

 

 

 

 



MMO COATED DISC FOR CATHODIC PROTECTION

clock September 20, 2023 15:32 by author admin

MMO/Platinised Disc, Elliptical and Strip Anodes are grown explicitly for security of Dam and Navigation lock entryways. Since our disc, elliptical & strip anodes are intended to work in new, saline and seawater conditions - utilized in other appropriate applications incorporates marine designs, water tanks and vessels. With a discretionary essential seal spacer gasket, it very well may be utilized within pipes, siphons, water tanks or other bended surfaces as well.

Disc anodes can be installed in dividers of boat bodies, condenser/water box, siphon inward/outside attractions and release to safeguard for longer years. It will be protected with rubber treated form to safeguard from disintegration. While utilizing MMO covered rubber treated plate anode to safeguard the boat structure from ocean water consumption, outside flow are applied to change over high expected anodic locales on a boat frames to low-likely cathodic destinations This ensures that ship hull surface is protected from corrosion.

 

         For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

 



CP COUPON FOR CATHODIC PROTECTION

clock August 9, 2023 14:10 by author admin

CP coupons and soil corrosion probes (SCPs) can be effective tools in applying CP criteria under challenging operating environments, such as cross-bonded systems or in high resistivity soil environments.

CP coupons are used for measuring polarized ("off") or depolarized (100 mV) potentials on pipelines and other structures, and are useful in situations where these type of potentials cannot be measured easily. This is usually in situations such as cross-bonded systems or structures in fluenced by interference from CP systems not controlled by the main protected system operator, or if it is not practical to simultaneously switch off numerous sources of CP current connected to the pipeline being tested.

SCPs are used to measure the metal corrosion rate, and are connected to the structure so that they receive the same level of CP as the structure. Thus even if the measured potential reading on the structure is not at the minimum required level, the corrosion rate measurement (mils per year, or microns) can be used as an alternative criterion to asses CP effectiveness. Low levels of polarization in high resistivity soils, or erroneous potential readings due to poor soil contact are examples of situations where SCPs can be useful.

 FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

 CU/CUSO4 PORTABLE REFERENCE ELECTRODE

 



MMO COATED TUBULAR STRING FOR CATHODIC PROTECTION

clock July 6, 2023 09:50 by author admin

We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.

MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.

Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion  can be prevented by eliminating the oxygen or the positively charged hydrogen ions.

FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

 

MMO_COATED_TUBULAR_STRING



MMO COATED TUBULAR STRING FOR CATHODIC PROTECTION

clock May 31, 2023 10:32 by author admin

We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.

MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.

Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.

Material

MMO Titanium

Usage/Application

Cathodic Protection ICCP

Brand

Tiaano

Thickness

Wall Thickness 0.9 mm

Country of Origin

  Made in India

 

FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

 



MMO COATED TUBULAR STRING FOR CATHODIC PROTECTION

clock May 31, 2023 10:15 by author admin

We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.

MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.

Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion  can be prevented by eliminating the oxygen or the positively charged hydrogen ions.

 

FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

 



MMO Coated Canister for Impressed Current Cathodic Protection

clock March 30, 2023 16:26 by author admin

 

Ti Anode Fabricators Pvt Ltd., manufactures CPCC Canister Anode with their in-house facilities in India, for Impressed current Cathodic protection application. Using following alternative anode combinations are been supplied based on the customer’s interest.

Titanium expanded mesh with Ti’s MMO coating.

Titanium wire with Ti’s MMO coating.

Titanium expanded mesh with Ti’s Platinum plating.

Titanium wire with Ti’s Platinum plating.

Niobium wire with Ti’s MMO coating.

Niobium wire with Ti’s Platinum plating.

Application:

􀂾 Shallow vertical and horizontal surface ground beds.

􀂾 Underground storage tanks.

􀂾 Aboveground storage tanks.

􀂾 Pipelines.

Advantages over Silicon - Iron anodes:

Twice the life

Unbreakable

Lighter weight

Easier to install

Narrower trench

Easy to centralize

Reduce excavation and drilling cost.

Material Of Construction:

Canister: Galvanized steel tube

Substrate: Titanium, ASTM B 265 or 348 Gr.1

Niobium, ASTM B

Catalyst: MMO or Pt

Cable: XLPE/PVC, EPR/CSPE, KYNAR/HMWPE.

Cable ~ anode connection: CPCC equal to LIDA.



MMO COATED TUBULAR STRING FOR CATHODIC PROTECTION

clock February 2, 2023 11:30 by author admin

We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.

MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.

Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.

Material

MMO Titanium

Usage/Application

Cathodic Protection ICCP

Brand

Tiaano

Thickness

Wall Thickness 0.9 mm

Country of Origin

  Made in India

 

FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com



MMO COATED RIBBON-6.35W & CONDUCTOR BAR-12.7W FOR CATHODIC PROTECTION

clock December 2, 2022 11:40 by author admin

Titanium Conductor Bar is designed to distribute cathodic protection current to a MMO titanium-based anode system. The conductor bar is highly resistant to corrosion in various environments.

Titanium conductor bar generally joins to MMO ribbon anode by spot welding to form a grid pattern under the tank which provides even distribution of current for cathodic protection of above ground storage tank bottoms and in concrete structures.

It is generally used along with MMO ribbon anodes and MMO mesh anodes for cathodic protection of above ground storage tank bottoms and in concrete structures. Titanium conductor bar and MMO ribbon anode for storage tank bottom cathodic protection.

It has a complete production line for ICCP MMO anode, the products they can provide are MMO ribbon anode, MMO tubular anode, MMO canister anode, MMO linear anode, etc.

Applications

           Bridge substructures

Buried sub structures

Reinforced concrete structures

Underground and above ground storage tanks.

Features

Conveniently cut and welded in the field

Easy installation

Surface mounted

Low system electrical resistance

Durable

Lightweight

Dimensionally stable

Economical.

MMO COATED RIBBON-6.35W

MMO coated ribbon anode is highly conductive and the anodes have a very low consumption rate. This combination of characteristics results in a long-life expectancy even when the anode is subjected to a high current density rating. MMO ribbon is commonly used for ICCP system of above ground storage tanks. MMO ribbon can be also used for new and old structures and steel reinforced concrete structures

Long lifetime and durable (Over 50 years)

Light weight (Easy transportation and handling)

Flexible (Quick installation)

Reliable, dimensional stability

 Excellent resistance in acidic medium

 

FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

  CONDUCTOR_BAR-12.7W

 

 

 



MMO COATED TUBULAR STRING FOR CATHODIC PROTECTION

clock December 2, 2022 11:09 by author admin

Titanium tubular anodes are manufactured using titanium seamless tube and coated with platinum group precious metal mixed oxide coating. Titanium tubular string for pipelines are arranged in ground beds either distributed or in a deep vertical hole depending on several design and field condition factors including current distribution requirements

Mixed Metal Oxide Coated Titanium anode design for the demands of deep anode beds, shallow beds and the earth’s natural waters. MMO Tubular anodes are dimensionally stable anodes which remain constant throughout all of the anode life, thus providing a constant performance with a low resistivity.

MMO Titanium tubular anodes are a titanium tube base with a mixed metal oxide conductive coating and itself an excellent electronic conductor.

The design life of the anode varies with operating current in a variety of applications from seawater to soil. Tubular Anodes are available in a number of diameters, lengths, current carrying capacities and life ratings.

MMO tubular anode can be in single or in string, it is generally adopting titanium tubular as substrates and coated with a mixed metal oxide catalyst.

Mixed metal oxide based electro catalytic anodes are a different type of anodes when compared to conventional anodes. These anodes are dimensionally stable, long life anodes that are not consumed during the process of generating cathodic protection current.

Benefits of MMO Coated Tubular String:

    Lightweight/Durable

    High current output

    Low cost

    Dimensionally stable

    High cost performance

MMO Coated Tubular String - Applications:

Salt, fresh and brackish water

Deep well Anodes

Marine applications

Tank bottoms

Underground pipelines

 MMO_COATED_TUBULAR_STRING

F      For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

 

 

 

 

 