September 25, 2023 12:49 by
admin
REFERENCE ELECTRODE
A reference electrode must have specific electrical, physical and chemical properties. It must facilitate the measurement of accurate pipe/soil/reference electrode potentials on pipelines. It must ideally have a stability that is sustainable for years. For this to occur it should not be polarized by the very low electrical current that will flow in a measurement circuit. The potential should be measured with a high impedance multi-meter or voltmeter.
Reference electrode allows you to measure the potential of the working electrode without passing current through it while counter (auxiliary) electrode allows you to pass current. If oxidation occurs at the working electrode, reduction using the same magnitude of current is sustained at the counter electrode and hence there is no current flow between working and reference electrode(high input impedance) enabling us to follow changes in working electrode potential accurately. This is not possible in a two electrode system although we can get crude values by using certain types of electrodes which can act simultaneously as working and reference electrode.
Tiaano supplying reference electrodes like zinc, AgAgcl for the pipeline, jetty etc.,
Our recent supply of MMO Coated Cantilever anode and reference electrode to our Calcutta customer:
For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

96621915-b678-48cf-ab83-79ffd12dfeb9|1|5.0|27604f05-86ad-47ef-9e05-950bb762570c

October 27, 2022 11:31 by
admin
Ag/Agcl Reference Electrode is the silver/silver chloride reference electrode is composed of a silver wire, sometimes coated with a layer of solid silver chloride, immersed in a solution that is saturated with potassium chloride and silver chloride.
Platinum titanium is a platinum metal oxide or platinum layer-coated on a titanium substrate. It is non-consumption, durable, and insoluble in the electrolyte. We can use platinum titanium anode for cathodic protection and electroplating.
Zinc Reference electrodes are generally implemented for the purpose of monitoring the anode in cathodic protection of buried or immersed metallic structures. It is made of high-purity Zinc alloy, ensuring accuracy and stability of potential measurements.
The electrode frame is made of stainless steel, coated carbon steel or Rubber. The electrode can be designed to fix in the structure. By means of specifically designed supports.
Cu/CuSO4 portable reference electrode implements a major usage in the cathodic protection System. Reference Electrode are in different shapes like disc, rod and strip with different dimension, which is also installed in the Heat exchanger to monitor the current supply of cantilever anodes.
MMO coated Canister anodes are commonly used for impressed current anode cathodic protection applications. These can be used to protect buried metallic piping in congested plant environments, to protect distribution or transmission pipelines in either distributed shallow ground beds or as horizontal remote ground bed anodes, and to protect other structures such as above ground or buried tanks and piling systems.

- Flexibility to meet various user needs;
- Produce complex shape of the anode;
- Energy-saving;
- Lightweight (especially the mesh grid anode);
- Longer working life under higher current density;
- Firm titanium structure, less deformation;
- Second platinized allowed;
- Uniform deposit, final products with high quality.
For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

2d2a88cb-3b4d-4659-962e-3192c0b71231|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

August 22, 2022 12:54 by
admin
Platinum titanium is a platinum metal oxide or platinum layer-coated on a titanium substrate. It is non-consumption, durable, and insoluble in the electrolyte. We can use platinum titanium anode for cathodic protection and electroplating.
Zinc Reference electrodes are generally implemented for the purpose of monitoring the anode in cathodic protection of buried or immersed metallic structures. It is made of high-purity Zinc alloy, ensuring accuracy and stability of potential measurements.
The electrode frame is made of stainless steel, coated carbon steel or Rubber. The electrode can be designed to fix in the structure. By means of specifically designed supports.
Ag/Agcl Reference Electrode is the silver/silver chloride reference electrode is composed of a silver wire, sometimes coated with a layer of solid silver chloride, immersed in a solution that is saturated with patassium chloride and silver chloride.
The Reference Electrode implements a major usage in the cathodic protection System. Reference Electrode are in different shapes like disc, rod and strip with different dimension, which is also installed in the Heat exchanger to monitor the current supply of Cantilever anodes.
- Flexibility to meet various user needs
- Produce complex shape of the anode
- Energy-saving
- Lightweight (especially the mesh grid anode)
- Longer working life under higher current density
- Firm titanium structure, less deformation
- Second platinized allowed;
- Uniform deposit, final products with high quality.
For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

ee10be0d-ddf1-4f33-97e4-a1b913433851|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

August 1, 2022 12:07 by
admin
The use of a metal reference electrode to measure potential difference in direct contact with the electrolyte around the structure may not make sense, but the reference zinc electrode in seawater is suitable for many applications. Successful samples have also been observed in the use of this electrode in the tanks bottom with the backfill, although many designs today use copper/ copper sulphate reference electrodes.
Zinc reference electrode is cheaper than silver/ silver chloride reference electrode and is used instead unless a high degree of stability is required. In addition, the mechanical stability of this type of electrode is much higher than other reference electrodes which have different and fragile components
High purity zinc ingots (minimum 99.9% with maximum iron content of 0.0014%) are used in the production of zinc reference electrodes. For connecting, a copper cable with chloride resistance coating and with 10 mm2 or 16 mm2 cross section is used and the cable is welded to the steel core inside the electrode. The interface between the copper cable and the steel rod is coated with epoxy resin.
MMO Coated cantilever anode are used to protect the surface of gigantic pump internals and condenser box where the sea water pass through in it. These anodes are use to protect the pump internals from erosion and corrosion with impressed current.
Reference electrodes are used in locations where a constant, stable reference where our anodes are installed with constant potential rectifiers.
Normally we can use wide variety of reference electrodes like zinc, silver chloride or copper sulfate reference electrodes for pump internal, condenser water box/vessel applications to monitor the cathodic protection anodes activeness.
Tiaano supplying MMO & platinum plated cantilever anodes and zinc reference electrodes for cathodic protection.
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

5c067b6d-5ad4-430d-a1cf-4ef5fbb2d5be|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 16, 2022 11:40 by
admin
Zinc Reference electrodes are generally implemented for the purpose of monitoring the anode in cathodic protection of buried or immersed metallic structures. It is made of high-purity Zinc alloy, ensuring accuracy and stability of potential measurements. The electrode frame is made of stainless steel, coated carbon steel or Rubber. The electrode can be designed to fix in the structure. By means of specifically designed supports.
These Zinc Reference Electrode implements a major usage in the cathodic protection System. Zinc reference Electrode are in different shapes like disc, rod and strip with different dimension, which is also installed in the Heat exchanger to monitor the current supply of Cantilever anodes.

Follow us on:
Pinterest, Instagram, Facebook, Twitter
9d93ceaa-27d3-4479-977f-3e9901facd8e|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

August 17, 2021 11:52 by
admin
Zinc Reference electrodes are generally implemented for the purpose of monitoring the anode in cathodic protection of buried or immersed metallic structures.
It is made of high-purity Zinc alloy, ensuring accuracy and stability of potential measurements. The electrode frame is made of stainless steel, coated carbon steel or Rubber. The electrode can be designed to fix in the structure. By means of specifically designed supports.
These Zinc Reference Electrode implements a major usage in the cathodic protection System. Zinc reference Electrode are in different shapes like disc, rod and strip with different dimension, which is also installed in the Heat exchanger to monitor the current supply of Cantilever anodes.

bda6dc44-9e43-46d0-a052-48757703c5e5|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

December 26, 2020 11:36 by
admin
Normally Titanium is the noncorrosive nature, but nonconductive material. MMO Coating will give the conductivity in titanium as per the application and amperage. MMO Coated disc used in ship hull protection to avoid high corrosion in seawater. Zinc reference electrode will be placed in particular distance as per the cathodic protection system to monitor the conductivity of the MMO coating disc.
Tianno supplying MMO coating disc for Navy ships as well as abroad clients.

b2e58994-b3c3-4852-8ba2-2b15559d516d|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

December 24, 2020 16:08 by
admin
Platinized FRP insulated strip for Cathodic protection of jetty piles and monitored by zinc reference electrodes
Platinized Titanium anodes take advantage of the low consumption rate and high current density. Voltages in excess of 10 Volts will result in severe pitting of the titanium core causing premature failure. Exterior protection of ships hulls - anodes in the shape of plates, discs or strips
Platinized FRP insulated strip Anode with impressed current leads to protect the hull of the ships. Negative terminal which is connected to ship hull and positive terminal with impressed current anodes.
Underwater steel structures protection like wharves, jetties, sheet pile walls and piers. Usually rod type anodes distributed throughout the structure to be protected to give a good overall protective current distribution.
Change in the potential of an electrode as the result of current flow to or from that electrode. Also, a change in the potential of a corroding metal from its natural steady-state value, as a result of current flow. “Depolarization” is the reverse process of Polarization. Depolarization is sometimes referred to as "hypo polarization”.
FRP Insulated strip and Zinc reference electrode

20706bd2-ac76-4987-9e50-0e3ddb702446|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

December 4, 2019 13:49 by
admin
MMO Coated cantilever & Zinc Reference electrodes
MMO Coated cantilever anode are used to protect the surface of gigantic pump internals and condenser box where the sea water pass through in it. These anodes are use to protect the pump internals from erosion and corrosion with impressed current.
Reference electrodes are used in locations where a constant, stable reference where our anodes are installed with constant potential rectifiers.
Normally we can use wide variety of reference electrodes like zinc, silver chloride or copper sulfate reference electrodes for pump internal, condenser water box/vessel applications to monitor the cathodic protection anodes activeness.
Tiaano supplying MMO & platinum plated cantilever anodes and zinc reference electrodes for cathodic protection.
Recent supply for our Singapore client