July 6, 2023 09:50 by
admin
We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.
MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.
Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

a49ff138-21a4-41c8-bf03-98fba5dc3220|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 29, 2023 12:50 by
admin
We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.
MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.
Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

f389d9b4-160b-4490-a1f2-e6b195a070e1|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 29, 2023 10:16 by
admin
MMO Coated Titanium Wire Anode is suitable for direct burial in fine sand, carbonaceous back fill or immersion in fresh or saline water.
The design life of the anode depends on the operating current in various applications from soil to seawater. The anodes are manufactured in three diameters: 1.0mm, 1.5 mm and 3.0mm. Due to the extremely low consumption rate of the coating (measured in terms of milligrams per year) at different current output, the projected life of the anodes varies from 15 to 50 years.
- Underground Storage Tank
- Above ground Storage Tank
- Ground Beds
- Pipeline
- Electrical Cable Shielding
- Water treatment equipment
- Canister Wire Anode

f575c8c0-1460-4696-bfa2-aac71b138c06|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 22, 2023 10:53 by
admin
MMO COATED CANTILEVER
Vessels, pipelines, condenser box and tanks which are used to store or transport liquids can also be protected from corrosion on their internal surfaces by the use of cathodic protection. By passing the DC current through the cantilever which is coated with platinum or MMO (mixed metal oxide) the cathode will be protected and could be monitor by the reference electrodes.
Tiaano supplying anodes as per the customer design and as well as our own design.
REFERENCE ELECTRODE
A reference electrode must have specific electrical, physical and chemical properties. It must facilitate the measurement of accurate pipe/soil/reference electrode potentials on pipelines. It must ideally have a stability that is sustainable for years. For this to occur it should not be polarized by the very low electrical current that will flow in a measurement circuit. The potential should be measured with a high impedance multi-meter or voltmeter.
Reference electrode allows you to measure the potential of the working electrode without passing current through it while counter (auxiliary) electrode allows you to pass current. If oxidation occurs at the working electrode, reduction using the same magnitude of current is sustained at the counter electrode and hence there is no current flow between working and reference electrode(high input impedance) enabling us to follow changes in working electrode potential accurately. This is not possible in a two electrode system although we can get crude values by using certain types of electrodes which can act simultaneously as working and reference electrode.
Tiaano supplying reference electrodes like zinc, Ag/Agcl for the pipeline, jetty etc.
For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

acab7e13-6102-4a36-8b55-e6cdd1c5ef3e|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 22, 2023 10:16 by
admin
Reference electrodes are generally implemented for the purpose of monitoring the anode in cathodic protection of buried or immersed metallic structures. It is made of high-purity of alloys, ensuring accuracy and stability of potential measurements.
The electrode frame is made of stainless steel, coated carbon steel or Rubber. The electrode can be designed to fix in the structure. By means of specifically designed supports.
These Reference Electrode implements a major usage in the cathodic protection System. Reference Electrode are in different shapes like disc, rod and strip with different dimension, which is also installed in the heat exchanger to monitor the current supply of cantilever anodes.
Cantilever anode is used for protecting pipeline internals, suction and condenser box internal for 30 years and more by applying DC current with transformer rectifier.
Normally titanium is well known for its high resistance to corrosion both water and chemical media but titanium is the poor electricity conductor. So we use platinum/ MMO plating/ coating to increase the conductivity.
For Enquiries please drop your email at dsa@tiaano.com|dsasupport@tiaano.com

45f6cd8b-a37f-4a28-b73e-837276dc2d5d|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 7, 2023 16:10 by
admin
The invention relates to the field of cathodic protection of reinforced concrete structures, and in particular to a design of discrete anode for cathodic protection suitable for being installed inside holes or slits made in the concrete. The anodes commonly used for the cathodic protection of reinforced concrete consist of a titanium substrate coated with transition metal oxides or other types of catalysts for anodic oxygen evolution.
Discrete anodes are not suitable for all applications, especially for thin concrete element or where the reinforcement is randomly spaced within a structure. The main area of application of discrete anodes would be thick reinforced concrete elements, such as beams, headstocks or piles in tidal/ splash zones where the application of ribbon anodes leads to grout acidification in most cases. Having in mind the long term durability of the cathodic protection components installed permanently in concrete and the importance of delivering a CP system with low maintenance.
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

3db140f1-d2d4-4456-9164-8e93169a62e8|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

June 2, 2023 09:48 by
admin
Ti Anode Fabricators Pvt Ltd., manufactures CPCC Canister Anode with their in-house facilities in India, for impressed current cathodic protection application. Using following alternative anode combinations are been supplied based on the customer’s interest. Titanium expanded mesh with Ti’s MMO coating. Titanium wire with Ti’s MMO coating. Titanium expanded mesh with Ti’s Platinum plating. Titanium wire with Ti’s Platinum plating. Niobium wire with Ti’s MMO coating. Niobium wire with Ti’s Platinum plating.
Application:
· Shallow vertical and horizontal surface ground beds.
· Underground storage tanks.
· Above ground storage tanks.
· Pipelines.
Advantages over Silicon - Iron anodes:
Twice the life, Unbreakable, Lighter weight, Easier to install, Narrower trench, Easy to centralize, Reduce excavation and drilling cost.
Material of Construction:
Canister: Galvanized steel tube
Substrate: Titanium, ASTM B 265 or 348 Gr.1
Niobium, ASTM B
Catalyst: MMO or Pt
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

efb8e614-bf25-4c95-a061-4115fa554e30|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

May 31, 2023 10:32 by
admin
We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.
MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.
Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.
|
Material
|
MMO Titanium
|
|
Usage/Application
|
Cathodic Protection ICCP
|
|
Brand
|
Tiaano
|
|
Thickness
|
Wall Thickness 0.9 mm
|
|
Country of Origin
|
Made in India
|
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

be0a50ea-ed06-4eed-8f12-da156ede251e|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

May 31, 2023 10:15 by
admin
We, Ti Anode Fabricators Pvt. Ltd., developed an extremely strong and electrically low resistance centre crimp connection, which ensures the lowest possible electrical resistance (less than 1.0 Milli Ohm) between the cables and anode tube. The Platinum group Mixed Metal Oxide coating is a crystalline electrically conductive coating that activates and enables a titanium substrate to function as an anode. Whether operating in fresh water, seawater, soil, or mud. MMO Coatings are extremely stable even in very low pH environments.
MMO titanium tubular anodes are coated with mixed metal oxide that has an extremely low consumption rate measured in milligrams per year. Unlike other types of anodes the consumption rate of MMO anode is negligible with the dimensions of the anode element remaining virtually unchanged during the operational service life of the anode. As a result, the power required to impress current will remain the same.
Cathodic protection system is a technique used to control a corrosion of a metal surface by making it the cathodic side of an electrochemical cell. Cathodic protection is an old and effective system that prevents forming rust in metal and helps in corrosion resistant. Corrosion can be prevented by eliminating the oxygen or the positively charged hydrogen ions.
FOR ENQUIRES PLEASE DROP YOUR EMAIL AT dsa@tiaano.com/dsasupport@tiaano.com

e0d76a54-491e-4750-9fb1-88da627f87fa|0|.0|27604f05-86ad-47ef-9e05-950bb762570c

May 30, 2023 09:48 by
admin
MMO piggyback anode is the flexible anode with a long life, which integrates the advantages of large current of MMO anode and excellent conductive performance. Due to its large current and small grounding resistance, it can be buried in the place far away from the anode structure.
Piggy pack anodes are used to protect the tank bottoms. It’s the easiest method of cathodic protection which may not need a weld at site and also easy to handle and install. Piggy pack wire anodes connected with cable by the way of Crimping and sealing with mastic and heat shrink sleeve procedure. The piggy pack anodes are inserted in the jacket with coke fill to sustain the conductivity of the anodes in the place where we install for cathodic protection.
Cathodic Protection is accomplished by applying a direct current to the tank surface of the metal, which causes the electrochemical potential of the structure to shift from a corroding state to a polarized and non-corroding state.

9bf8541d-f52c-4563-9ee2-4c773c3900fa|0|.0|27604f05-86ad-47ef-9e05-950bb762570c